Panel Mounting Nut Block

OEM / ODM Available Free Sample Available ISO 9001:2015 ISO 14001 RoHS REACH

Block that seats in the profile slot and provides a captive threaded hole at any position, so a panel or fitting bolts to the profile without drilling it.

Wholesale Price $0.12 - $1.60 / pc per pc
Material Zinc-plated steel, stainless steel or aluminium
Alloy Grade 6063-T5 on aluminium blocks
Temper custom
Section Size Fits 6, 8 and 10 mm slot profiles
Slot M5 / M6 / M8 / M10 thread
Length Block 15-40 mm depending on thread and variant
Tolerance ±0.15 mm on thread position
Surface Zinc plated, stainless or anodised
MOQ 500
Lead Time 15-25 days after deposit
Loading Port Shanghai / Ningbo
Supply Ability 400,000 pcs per month
Payment Terms T/T 30% deposit + 70% before shipment | L/C at sight
Trade Terms FOB | CIF | EXW
Certifications ISO 9001:2015 | ISO 14001 | RoHS | REACH
Request a Quote Reply within 24 hours

Panel installation · Captive thread

A panel mounting nut block seats in the profile slot and provides a threaded hole at any position along it. A bolt through a panel or a fitting screws into that hole and clamps the panel to the profile face. The block is the reason the profile does not have to be drilled: the thread lives in the block, which can be slid to wherever it is needed.

This is the same principle as a T-nut, but as a block rather than a nut. The block has more thread depth, so it takes a higher bolt torque and a higher load, and it locates square in the slot rather than relying on the nut rotating into position. Where a panel or a fitting has to be bolted to a profile with a real load on it, the block is the stronger choice.

The block, the nut and the bolt

Three parts make the joint: the block, which sits in the slot and carries the thread; the bolt, which passes through the panel or fitting; and the panel or fitting itself, which is clamped between the bolt head and the profile face. Tightening the bolt draws the block against the inside of the slot and clamps the panel to the profile.

The block’s advantage over a plain T-nut is thread depth and squareness. A T-nut is thin, so its thread engagement is limited and it can tilt as the bolt is tightened. A block is a solid piece with a full-depth thread, so it takes more torque and it stays square in the slot, which keeps the panel aligned.

Block sizeSlotThreadMax torqueLoad per point
M5 block6 mmM54 NmLight panel
M6 block8 mmM68 NmGeneral panel
M8 block8 mmM820 NmHeavy panel or fitting
M8 block long8 mmM820 NmPanel with a gasket
M10 block10 mmM1035 NmHeavy fitting
Standard blockA single threaded block that slides into the slot. The general-purpose version for panel and fitting fixings.
Long blockA longer body with more thread depth and more bearing area, for a thicker panel or a gasket that has to be compressed.
Double-thread blockTwo threaded holes in one block, used where a panel needs two fixings close together or where a fitting has a two-bolt pattern.
Slotted blockA block with a slotted thread so the panel can be adjusted slightly in or out before final tightening.

Practical point: count the fixings before you order. A panel with four corner fixings and no mid-edge support will rattle in the middle, so the block count for a panel is usually two per edge rather than one per corner. We will count the fixings from your panel drawing on request.

  1. Confirm the slot and the thread The block is sized to the slot and the thread is chosen for the load. A 6 mm slot takes an M5 block; an 8 mm slot takes M6 or M8.
  2. Slide the block into the slot Insert the block from the end of the profile, or through a slot opening, and slide it to the fixing position.
  3. Offer up the panel Offer the panel to the profile and align the fixing holes with the block threads. Slide the blocks to suit if the holes are not exactly where expected.
  4. Fit the bolts and tighten Start the bolts by hand, then tighten to the torque for the thread size. Do not over-torque — the block thread is the limit.
  5. Check the panel is seated Look along the panel edge. A gap means a block has not drawn up square, which usually means a bolt is cross-threaded.

Frequently asked questions

How is this different from a T-nut?

A block has a full-depth thread and flats that engage the slot, so it takes more torque and stays square. A T-nut is thinner, engages less thread and can rotate as the bolt is tightened.

Can the block be fitted after the frame is built?

Yes, it slides in from the end of the profile or through a slot opening, and it can be positioned anywhere along the slot.

What torque can the block take?

Around 8 Nm for an M6 block, 20 Nm for M8 and 35 Nm for M10. The block thread is the limit, so do not over-torque.

How many blocks does a panel need?

Two per edge is the usual figure, including the mid-edge positions. A panel with only corner fixings will rattle in the middle.

Are the blocks available in stainless?

Yes, for wash-down and outdoor panels, with stainless bolts to match so the fixing does not corrode.

Send the panel drawing and the fixing points

Tell us the panel, the fixing pattern and the load at each point. We will recommend the block, the thread size and the count, and return FOB pricing within one working day.

Request a Quote