Levelling foot with a drilled base pad so the frame can be anchored to the floor after levelling, resisting vibration, sliding and tipping loads.
| Material | Steel base with nylon insert, or stainless steel; zinc-plated stem |
|---|---|
| Alloy Grade | Not applicable |
| Temper | custom |
| Section Size | Fits profile ends with M10-M20 thread insert |
| Slot | M10 / M12 / M16 / M20 stem; 2-4 drilled or slotted holes |
| Length | Stem 50-100 mm; overall height 70-175 mm |
| Tolerance | ±0.3 mm on hole positions |
| Surface | Zinc plated; stainless option |
| MOQ | 200 |
| Lead Time | 15-25 days after deposit |
| Loading Port | Shanghai / Ningbo |
| Supply Ability | 120,000 pcs per month |
| Payment Terms | T/T 30% deposit + 70% before shipment | L/C at sight |
| Trade Terms | FOB | CIF | EXW |
| Certifications | ISO 9001:2015 | ISO 14001 | RoHS | REACH |
Levelling feet · Floor anchoring
A swivel foot with mounting holes is a levelling foot whose base pad carries two or four drilled holes. The frame is levelled first, then the pad is bolted down through those holes, so the foot does both jobs in one operation: it takes out the floor unevenness and it anchors the frame so it cannot move.
This is the foot specified wherever a frame has to stay put. A machine tool that generates vibration, a press, a conveyor transfer, a frame in a seismic zone or a frame that a vehicle can nudge all need to be anchored, not just levelled. Levelling alone leaves the frame resting on friction, and friction is not a restraint.
A standard levelling foot does one thing: it lets the height of each corner be set independently so the frame sits level. The frame is then held in place by its own weight and by friction between the pad and the floor. On a static bench that is enough. On anything that vibrates, slides or has to resist a lateral push, it is not.
Bolting the pad to the floor changes the load path completely. Instead of friction resisting a sideways push, the bolts resist it in shear, and the frame is restrained against sliding and against tipping. On a tall machine frame this is the difference between a stable installation and one that walks across the floor over a shift.
| Stem | Pad Ø | Fixing holes | Anchor bolt | Static load |
|---|---|---|---|---|
| M10 × 50 mm | 50 mm | 2 × Ø9 mm | M8 | 600 kg |
| M12 × 60 mm | 60 mm | 4 × Ø11 mm | M10 | 1,000 kg |
| M16 × 80 mm | 80 mm | 4 × Ø13 mm | M12 | 2,000 kg |
| M20 × 100 mm | 100 mm | 4 × Ø15 mm | M12 / M14 | 3,500 kg |
The foot is supplied with drilled holes; the anchor bolt is chosen for the floor. A cast concrete slab takes a mechanical expansion anchor or a chemical anchor. A raised floor or a timber deck needs a through-bolt and a load-spreading plate underneath. A floor with a screed over insulation needs a longer anchor that reaches the structural slab.
Tell us the floor build-up and we will specify the anchor type and the bolt length with the foot. Getting this wrong is the most common reason an anchored frame comes loose: the anchor is the right size but reaches only into the screed, not into the slab that is doing the holding.
Practical point: if the frame has to be moved for maintenance, specify a foot with slotted rather than plain holes. The bolts are then slackened and the frame slides out without the anchors being removed.
Only if the holes are slotted, or if the adjustment is made before the bolts are tightened. On a plain-hole foot, level the frame first and anchor second.
It depends on the floor. Cast slab takes a mechanical or chemical anchor; a raised or timber floor needs a through-bolt with a spreader plate. Send the floor build-up and we will specify.
It improves the resistance to lateral and tipping loads, but the vertical compression rating of the foot is unchanged. Keep the three-foot derating for vertical load.
No, provided the holes are outside the high-stress zone under the stem. The pad diameters we supply for drilled feet are sized so the holes do not reduce the load capacity.
Yes, for wash-down and outdoor installations, with stainless anchor bolts to match so the installation does not develop a galvanic corrosion problem.
Tell us the frame weight, the floor construction and whether the frame has to be movable for maintenance. We will return the foot, the anchor bolt type and FOB pricing within one working day.
Request a Quote