40 x 40 mm T-slot aluminium machine guard frame for safety fences and enclosures, built to ISO 14120 principles with mesh or polycarbonate infill.
| Material | Aluminium |
|---|---|
| Alloy Grade | 6063-T5 |
| Temper | T5 |
| Section Size | 40 x 40 mm post and rail |
| Slot | 8 mm groove, M6 and M8 slot nuts, 30 mm slot centres across the corner |
| Length | Cut to drawing, post and rail to +/-0.5 mm |
| Tolerance | EN 755-9, wall +/-0.15 mm |
| Surface | Mill finish / clear anodised / black anodised |
| MOQ | Made to order; single frames from stock components |
| Lead Time | Typically 2 to 3 weeks for the cut and machined frame, plus a week for anodising |
| Loading Port | Shanghai, Ningbo, Qingdao |
| Supply Ability | In-house cutting, machining and assembly capacity for guard frames |
| Payment Terms | T/T 30 per cent deposit, balance against copy of bill of lading |
| Trade Terms | FOB, CIF, CFR, EXW |
| Certifications | Mill certificate to EN 10204 3.1 on request, RoHS and REACH declarations |
No. A guard is a safety device, not a fence. It must keep an operator’s hand or body part from reaching a hazard, which is a dimensional requirement set out in ISO 14120. The aluminium frame is the structural part; the mesh or panel infill and the door interlocks are what actually make it a guard.
It is the standard for the design of machine guards. The key principle is that the guard must prevent access to the hazard, which means the openings must be small enough, and the distance between the guard and the hazard large enough, that a hand or finger cannot reach through. Section 04 gives the opening sizes.
Aluminium T-slot goes together without welding and without heat, so it is faster to build and easy to modify when the machine changes. It is lighter than steel, does not rust, and the slots carry the mesh or panels directly. The trade is that aluminium is softer than steel, so the frame must be sized for the expected impact.
| Item | Value | Note |
|---|---|---|
| Post and rail | 40 x 40 mm | 40 series T-slot |
| Groove | 8 mm | 30 mm slot centres across the corner |
| Fixings | M6 and M8 slot nuts | mesh clips and panel retainers |
| Wall | light / standard / heavy | weight 1.30 to 2.35 kg/m |
| Infill | mesh or polycarbonate | in the slot or a panel retainer |
| Doors | hinged, with interlock | switch wired to the safety circuit |
| Alloy | 6063-T5 | EN AW-6063 |
| Standard | ISO 14120 | guard design principles |
A machine guard does four things at once, and each one drives part of the design.
The frame is sized for the first two jobs; the infill and door are specified for the second two.
The guard works by making the openings small enough that a hand cannot reach through to the hazard. ISO 14120 links the opening size to the minimum distance between the guard and the hazard.
| Opening size (mm) | Min distance to hazard (mm) | Typical infill |
|---|---|---|
| up to 4 | 0 | solid panel |
| 4 to 8 | 15 | fine mesh |
| 8 to 25 | 120 | standard mesh |
| 25 to 40 | 200 | coarse mesh |
| over 40 | 850 or more | not suitable for direct guarding |
The distances are indicative and depend on the specific hazard. For a safety-critical guard, an engineer should verify the opening size and distance against the current ISO 14120 edition for the machine in question. This page is a design guide, not a certification.
The 40 x 40 mm frame is sized for light to medium impact. It will hold a mesh or polycarbonate panel and resist an operator leaning on it, but it is not a crash barrier.
| Wall | Weight (kg/m) | Typical use |
|---|---|---|
| light | 1.30 | static guards, no impact expected |
| standard | 1.8 | guards with occasional contact or lean |
| heavy | 2.35 | guards near ejecting parts or moving loads |
If the hazard can eject a part at high speed, the infill and frame must be engineered for that energy. In that case, a welded steel guard or a polycarbonate panel rated for the impact is usually the right answer.
| What goes wrong | Why it happens | Design it out by |
|---|---|---|
| Hand reaches through the opening | opening size or distance to hazard is wrong | verify opening and distance against ISO 14120 for the hazard |
| Door bypasses the interlock | the switch is not wired into the safety circuit | wire the interlock into the machine’s safety-rated stop circuit |
| Frame deforms on impact | the wall is too light for the expected impact | use the heavy wall near ejecting parts, or a welded steel guard |
| Mesh pulls out of the slot | the mesh clip is too light for the tension | use mesh retainers rated for the panel tension |
| Guard is removed and not replaced | the guard is awkward to open and operators bypass it | make the door hinged and counterbalanced so it is easy to use |
The frame is designed to the principles of ISO 14120, but compliance is machine-specific. An engineer must verify the opening size, distance and interlock for the hazard in question. We build to your specification.
Yes. The panel sits in the slot or in a panel retainer, fixed with M6 or M8 slot nuts. Polycarbonate gives full visibility and better containment than mesh.
For light to medium impact, yes, when sized correctly. For hazards that can eject parts at speed, use the heavy wall or a welded steel guard.
Yes. The T-slot system lets you add a hinged door and an interlock without rebuilding the frame.
1.30 to 2.35 kg/m depending on the wall you select.
Yes. Anodising is common for clean room and food environments, where the frame must be easy to clean.
Send those six items and the quotation comes back with the frame, infill, door hardware and finish broken out separately. Browse the full aluminium profile catalogue and the 40 series aluminium profiles range.
Send the hazard, dimensions, infill and door details. We quote the frame, infill and hardware as separate lines.
Request a quotation