PG40 80×40 mm Six Slot Super Light Aluminium Strut Profile for Enclosures

OEM / ODM Available Free Sample Available ISO 9001:2015 EN 755-9 RoHS REACH

An 80 x 40 mm six slot super light PG40 aluminium strut profile with reduced walls. For enclosure covers, exhibition frames and light guarding where weight matters more than tapped connections.

Wholesale Price $2.80 - $4.60 / m per m
Material Aluminium
Alloy Grade 6063-T5
Temper T5
Section Size 80 x 40 mm
Slot 6 x 10.2 mm groove, 8 mm mouth, 40 mm pitch, outer pair 40 mm apart, M8
Length 6 m stock, cut to drawing to +/-0.5 mm
Tolerance EN 755-9 / GB/T 6892, wall +/-0.15 mm
Surface Mill finish / clear anodised / black anodised
MOQ 300
Lead Time 18-28 days after deposit for mill finish
Loading Port Shanghai / Ningbo
Supply Ability 350 t per month
Payment Terms T/T 30% deposit + 70% before shipment | L/C at sight
Trade Terms FOB | CIF | EXW
Certifications ISO 9001:2015 | EN 755-9 | RoHS | REACH
Request a Quote Reply within 24 hours

Structural framing · PG40 super light beam

A PG40 80 x 40 mm six slot super light aluminium strut profile is a reduced-wall version of the standard 80 x 40 mm beam. The envelope, the slot layout, the 40 mm pitch, the 10.2 mm groove and the 8 mm mouth are all unchanged, so every standard 40 series bracket, nut, cap and cover still fits. It weighs about 2.1 kg/m against roughly 3.0 kg/m for a standard wall, and it is supplied in 6063-T5.

A super light section is a genuine engineering choice, not a cheap one, and it is worth knowing exactly what you are trading. Keeping the slot geometry identical means you keep the whole accessory system; thinning the walls means you lose two things that no bracket can restore — the ability to tap a thread, and the ability to clamp hard. Both of those follow directly from the wall thickness, and both have to be designed around rather than worked around.

Cross-section drawing of an 80x40 mm six slot super light PG40 aluminium strut profile showing the reduced wall thickness and 10.2 mm grooves
80 x 40 super light section: the same slot geometry as the standard beam, with the weight taken out of the walls.

What was kept and what was given up

The design of a super light section is deliberately conservative in one respect and aggressive in another. The external geometry is untouched, so the section is a drop-in replacement for the standard beam and no bracket has to be redesigned. The walls, however, are reduced, and that is where all the saving comes from.

Standard 80 x 40 mmSuper light 80 x 40 mm
Envelope80 x 40 mm80 x 40 mm
Slots6 x 10.2 mm on a 40 mm pitch6 x 10.2 mm on a 40 mm pitch
Slot mouth8 mm8 mm
Bracket compatibilityStandard 40 seriesStandard 40 series
Weightapprox. 3.0 kg/mapprox. 2.1 kg/m
Bending stiffnessReferenceAbout 40 per cent of the reference
Tappable corner holesYes, with careNo
Slot torque ceilingAbout 15 N m for M8About 8 to 10 N m for M8

The saving is in the wall, and so are the limits. A 30 per cent weight saving is worth having on a large cover or a long exhibition frame. It is not worth having if the design depends on a tapped connection or a heavily clamped joint, because neither can be recovered by using more hardware.

Limit one: you cannot tap it

A thread in aluminium needs about one diameter of engagement as an absolute minimum and one and a half diameters for full strength. An M8 thread therefore needs 8 to 12 mm of material. On a super light section the flange is well under half of that, so a tapped hole in the flange is not available at all — not marginal, but impossible.

The consequence is that every connection on a super light section has to go through a slot with a nut. That is a perfectly good method and it is how the whole system is designed to work, but it changes the design: you cannot bolt something to the end face of the beam, you cannot use an end face connector, and you cannot use a self-tapping screw connector. The connection vocabulary shrinks to brackets and slot nuts.

Limit two: the slot lip deforms

The slot mouth is an undercut — 8 mm wide against a 10.2 mm groove. The lip above that undercut is part of the flange, and on a super light section the flange is thin. When a nut is tightened, the load path goes from the nut, into the lip, and into the flange. If the lip deforms, the nut no longer sits square in the groove, the contact area drops, and the joint loosens under vibration.

In practice that means keeping the tightening torque down. A standard wall 40 series section will take about 15 N m on an M8 nut; on a super light section, stay around 8 to 10 N m. The rule that follows is worth writing into the assembly instructions: use more fixings rather than tighter ones.

Fixing methodAvailable on a super light section?What to do instead
Tapped hole in the flangeNo, not enough wallUse a slot nut in the groove
End face connector into the core boreNo, no thread availableUse a bracket, or choose a heavier section
Self-tapping screw connectorNo, no thread can be formedUse a bracket and slot nuts
M8 slot nut in the grooveYes, the standard methodTorque to about 8 to 10 N m
Tapped hole in the 11 mm webMarginalOnly where the web has the full wall thickness

The load ceiling

With the section mounted the sensible way — the 80 mm dimension vertical, which gives about 43 cm4 — the deflection limits work out as follows for a simply supported beam at an L/500 limit.

SpanMax distributed load at L/500Max central point load at L/500Verdict
0.6 mapprox. 12.8 kNapprox. 8.0 kNFine for a frame rail
0.8 mapprox. 7.2 kNapprox. 4.5 kNFine for a frame rail
1.0 mapprox. 4.6 kNapprox. 2.9 kNFine for a cover or a guard
1.2 mapprox. 3.2 kNapprox. 2.0 kNLight loads only
1.5 mapprox. 2.1 kNapprox. 1.3 kNAdd a mid support

Those figures look generous until you put them next to the fixing limits. At a 1.2 m span the beam will carry 2 kN on paper, but the joints that hold it will have been torqued to 8 N m into a thin lip, and that is the real ceiling. On a super light frame the connections are almost always the limiting factor, not the section.

Where it is the right choiceEnclosure and machine covers, exhibition and display frames, lightweight guarding, duct and ductwork supports, and any large structure that is carried by hand or shipped.
Where it is the wrong choiceAnything anchored to a floor, anything tapped, anything clamped hard, and any member that carries a point load at mid-span over more than about 1 m.

Building a super light frame

  1. Design every joint as a bracket and slot nut joint No end face connectors, no self-tapping connectors, no tapped holes. Decide this at the drawing stage, not on the bench.
  2. Keep the torque at 8 to 10 N m The slot lip is the limit. A torque wrench is worth having on a super light frame more than on a heavy one.
  3. Use more fixings, closer together A 40 mm pitch gives you plenty of positions. Six lightly loaded joints outperform two heavily loaded ones on a thin section.
  4. Mount the 80 mm dimension vertical It gives about four times the stiffness of the flat orientation. On a section this light the orientation is the difference between usable and unusable.
  5. Add a mid support rather than a heavier section if it sags On a cover or a guard a support is cheap; on a super light section it is usually the right answer anyway.

Frequently asked questions

Can I tap the end of a super light profile?

No. The flange is far too thin for an M8 thread, and even an M5 thread needs more material than is available. Every connection has to go through a slot with a nut.

What torque should I use?

About 8 to 10 N m for an M8 slot nut, against about 15 N m on a standard wall section. The limit is the deformation of the thin slot lip.

Is it strong enough for a machine guard?

For a guard panel frame, yes. A guard’s job is to retain a panel, and the panel carries the impact. For a guard that has to stop a projectile, size the frame on the impact load and expect to step up a wall thickness.

Will standard brackets fit?

Yes. The envelope and the slot geometry are identical to the standard 80 x 40 mm beam, so every 40 series bracket, nut, cap and cover fits unchanged.

How much lighter is it?

About 2.1 kg/m against roughly 3.0 kg/m, so about 30 per cent. On a large cover or a long exhibition frame that is a significant handling and freight saving.

Send the frame size and whether anything is tapped

Tell us the overall frame size, the load and whether any connection has to be tapped. We will confirm whether the super light wall works or whether you need the standard section.

Request a Quote