Strut Aluminium Profile 30×30 mm 4-Slot Light T-Slot Extrusion

OEM / ODM Available Free Sample Available ISO 9001:2015 EN 755-9 RoHS REACH

30 x 30 mm light-wall four-slot T-slot strut aluminium profile in 6063-T5 with M5 grooves on all four faces and a O 10 mm centre bore tapped M12. About 0.95 kg/m for portable, low-cost frames with internal cable routing.

Wholesale Price $1.60 - $2.55 / m per m
Material Aluminium
Alloy Grade 6063-T5
Temper T5
Section Size 30 x 30 mm
Slot M5 groove, 4.5 x 4.5 mm, 6 mm mouth, 4 faces
Length 6 m stock, cut to drawing to plus or minus 0.5 mm
Tolerance EN 755-9 / GB/T 6892, wall plus or minus 0.12 mm
Surface Mill finish / clear anodised / black anodised
MOQ 800
Lead Time 16-26 days after deposit for mill finish
Loading Port Ningbo
Supply Ability 480 t per month
Payment Terms T/T 30% deposit + 70% before shipment | L/C at sight
Trade Terms FOB | CIF | EXW
Certifications ISO 9001:2015 | EN 755-9 | RoHS | REACH
Request a Quote Reply within 24 hours

Light wall · 30 series

A 30 x 30 light four-slot strut profile is a thin-wall T-slot aluminium extrusion with a slot on each of its four faces, an M5 groove of 4.5 x 4.5 mm inside a 6 mm mouth, a O 10 mm centre bore tapped M12, and a wall of about 1.2 to 1.4 mm. It weighs roughly 0.95 kg/m against about 1.30 kg/m for the standard wall of the same envelope. It is the section to specify when the frame has to be portable, cheap in quantity and easy to route cable through, and when the loads are light and short-span.

The trade for that weight is not one thing but four: the section deflects more, the M5 slot will not take the same tightening torque, the centre bore carries fewer usable threads, and the thin lips dent more easily in handling. None of those is a reason to avoid the section; they are the reason it has a boundary. Below about 800 mm between supports and about 200 N of load, the light wall behaves like the standard wall. Past roughly 1 m the difference stops being academic, and the answer is a standard-wall 30 series or a move up to the 40 series, not a heavier bolt.

Cross-section drawing of a 30x30 mm light-wall four-slot T-slot aluminium profile showing the 30 mm envelope, 4.5 x 4.5 mm M5 grooves, the O 10 mm centre bore tapped M12 and the thin 1.2 to 1.4 mm wall
30 x 30 light-wall four-slot section: 30 mm envelope, M5 grooves at 4.5 x 4.5 mm in a 6 mm mouth, O 10 mm centre bore tapped M12, wall about 1.2 to 1.4 mm.

What a light wall changes

Take the standard 30 x 30 four-slot die and run the walls down from 1.8 mm to about 1.2 to 1.4 mm and three things happen at once. The section gets lighter and cheaper, because material is the largest single cost in an extruded profile. The internal cavities get larger, because the same 30 mm envelope now has thinner walls around a bigger void. And the section gets more flexible, because bending stiffness depends on how far the material sits from the neutral axis, and thin walls move the material closer to the middle.

Material costRoughly 25 to 30 per cent less aluminium per metre than the standard wall, which tracks almost one to one into the price. On a high-volume frame programme this is usually the single reason the light die exists.
Weight and handlingAbout 0.95 kg/m instead of 1.30 kg/m. A 6 m length drops from about 7.8 kg to 5.7 kg, which is the difference between one person carrying a bundle and two, and between a frame that can be moved by hand and one that needs a trolley.
Free space for cableThin walls leave noticeably larger internal voids, and a four-slot 30 x 30 has four of them. Sensor and low-voltage cable can be run inside the section with a much higher fill ratio before it becomes hard to pull, which keeps wiring off the outside of a light machine cover.

The three costs of thin aluminium

Property30 x 30 light wall30 x 30 standard wall
Wall thickness1.2 – 1.4 mmapprox. 1.8 mm
Weightapprox. 0.95 kg/mapprox. 1.30 kg/m
Moment of inertiaapprox. 2.6 cm4approx. 3.6 cm4
Deflection, 300 N at 800 mm spanapprox. 1.75 mmapprox. 1.27 mm
Deflection, 300 N at 1200 mm spanapprox. 5.9 mmapprox. 4.3 mm
Usable tap depth in the centre boreapprox. 12 mmapprox. 16 mm
Sensible torque, M5 slot fixingapprox. 2.0 Nmapprox. 2.8 Nm
Relative material cost per metre100approx. 135

The quantified boundary

Read the deflection rows in that table as a serviceability check rather than a strength check. At 800 mm, the light wall moves 1.75 mm under 300 N, which is about L/457 and perfectly acceptable for a cover, a bench or a display frame. At 1200 mm the same load gives 5.9 mm, or L/203, and at that point the frame looks springy even though the stress in the aluminium is still low. The section has not become unsafe; it has stopped looking like a structure, which in most projects is the failure that matters.

Working boundary for the light wall: spans under 800 mm, loads under about 200 N, M5 fixings at low torque, and a frame that is carried rather than stood on. Beyond any one of those, step to the standard wall before considering a bigger bolt. For anything a person stands on, or any guard exposed to impact, start at the standard wall and check it.

Specifying a light-wall section

  1. State the wall on the order Light and standard wall look identical in a 2D layout and are the same envelope on the outside. If the wall is not written on the purchase order, the factory will supply whichever die is running, and the two are not interchangeable on a weight or stiffness calculation.
  2. Ask for the certified weight per metre The 0.95 kg/m figure is a planning number. Every die has its own wall and its own tolerance, so ask for the certified weight and the second moment of area on the specific die before the design is signed off.
  3. Decide the torque before the fastener Because the light wall caps tightening torque at roughly 2.0 Nm for M5, choose the joint detail around that limit: a larger number of fixings at lower torque rather than fewer fixings tightened hard. A joint that relies on high torque is a joint that will crush the lips.
  4. Plan the cable route with the section The extra internal volume is one of the genuine advantages of the light wall. Route the cable through the section from the start and put the exit points in the machining drawing, rather than drilling the frame on site and breaking the anodising.
  5. Fix the anodising class early On a 1.2 mm wall an anodic layer of 20 microns is a larger fraction of the material than on a standard wall, and it changes how a nut slides in the groove. Specify the class at enquiry wherever a nut has to move freely.

Fixing the light wall

The four M5 grooves take T-slot nuts and nothing else: there is no wall to tap. Corners are made with a light angle bracket or a butt connector inside the section, and because the section is light the bracket often sets the joint capacity rather than the extrusion. Panels are held with panel mounting blocks and the grooves closed with cover strip where the frame is visible.

For a light frame that has to be levelled, a small levelling foot or a base plate is usually enough. Where the frame has to sit flat on a floor, a base plate spreads the load and stops the thin wall from being crushed at the foot.

ESD assembly workbench frame built from light 30 series aluminium profile with internal cable routing
Light machine guard frame in thin-wall aluminium strut profile with panel infill
Light-wall 30 series in service: an ESD bench frame with cable run inside the section, and a light guard frame where weight and cost matter more than stiffness.

Frequently asked questions

How much lighter is the light wall than the standard wall?

About 0.95 kg/m against about 1.30 kg/m in the same 30 x 30 envelope, so roughly 27 per cent less material and a similar reduction in price. A 6 m length drops from about 7.8 kg to 5.7 kg.

Can I tap the slot wall of a light 30 x 30 profile?

No. At 1.2 to 1.4 mm there is not enough material for a reliable thread, so every slot fixing goes through a T-slot nut. The centre bore is tapped M12 but usable depth is limited to about 12 mm.

What torque can I use on the M5 slot fixings?

Around 2.0 Nm, against about 2.8 Nm on the standard wall. Above that the groove lips deform and the nut stops sliding, which cannot be corrected afterwards.

At what span should I stop using the light wall?

As a guide, keep the unsupported span under about 800 mm and the load under about 200 N. At 1200 mm the same 300 N load gives about 5.9 mm of deflection, which is visible. Past that, move to the standard wall or a larger section.

Do you supply it cut, machined and anodised?

Yes. We cut to plus or minus 0.5 mm, deburr, tap centre bores and slot ends, drill and counterbore to drawing, and supply mill, clear anodised or black anodised. Send DWG, DXF, STEP or PDF.

Send the load case, get a wall recommendation and a price

Tell us the span, the load and the torque the joint has to take. We will confirm whether the light wall is inside its boundary for your design, or quote the standard wall, then supply cut, tapped, anodised and bagged by assembly with FOB pricing.

Request a Quote