Rectangular base plate for 40 × 80 mm profiles with a full-perimeter EPDM gasket that seals the profile core against water and swarf entering the leg from the floor.
| Material | Aluminium 6063-T5 plate; closed-cell EPDM gasket |
|---|---|
| Alloy Grade | 6063-T5 |
| Temper | custom |
| Section Size | 40 x 80 mm rectangular profile |
| Slot | 4 x M8 end taps; 4 x Ø11 mm anchor holes |
| Length | Plate 80 x 120 mm; 8 or 10 mm thick |
| Tolerance | ±0.2 mm on hole positions; ±0.15 mm on thickness |
| Surface | Anodised 10-15 µm or powder coated |
| MOQ | 200 |
| Lead Time | 15-25 days after deposit |
| Loading Port | Shanghai / Ningbo |
| Supply Ability | 60,000 pcs per month |
| Payment Terms | T/T 30% deposit + 70% before shipment | L/C at sight |
| Trade Terms | FOB | CIF | EXW |
| Certifications | ISO 9001:2015 | ISO 14001 | RoHS | REACH |
Floor elements · Sealed base
This is the base plate for a 40 × 80 mm profile leg, and it is supplied with a gasket as standard. The gasket is the detail that separates it from a plain plate: it seals the open core of the profile against the plate, so water, coolant and swarf cannot enter the leg from the floor and travel up inside it.
On a frame in a wash-down area, a machine shop or an outdoor installation, an open profile core is a trap. Liquid that enters at the foot sits inside the extrusion and corrodes it from the inside, where it cannot be seen or cleaned. Sealing the base closes that path at the lowest point of the leg, which is where the water arrives.
A base plate on a rectangular 40 × 80 profile is bolted to the end taps and closes the end face. Without a gasket, the joint between the plate and the profile end is a capillary gap: liquid on the floor is drawn into it, and once inside the hollow core it has nowhere to drain and no airflow to dry it.
The result is a leg that looks sound from outside and is corroding on the inside. On an anodised profile the corrosion is slow but it is real, and it eventually reaches the bolts. A closed-cell gasket, compressed between the plate and the profile end by the plate bolts, stops the water at the joint.
| Item | Specification | Note |
|---|---|---|
| Profile | 40 × 80 mm rectangular | Matches the outside section |
| Plate size | 80 × 120 mm | Extends 20 mm beyond the profile on each side |
| Plate thickness | 8 mm standard; 10 mm heavy | Set by deflection |
| End taps | 4 × M8 | Standard 40 series end tap spacing |
| Anchor holes | 4 × Ø11 mm | For M10 floor anchors |
| Gasket | Closed-cell EPDM, 2 mm | Full perimeter, bolt bosses |
| Finish | Anodised or powder coated | Natural, black or grey |
A 40 × 80 leg is stiffer in one direction than the other, and the base plate has to match that. The plate is rectangular and its long axis follows the long axis of the profile, so the extra bearing area is where the leg is stiffest and the tipping moment is highest.
On a frame where the 40 × 80 leg carries a load offset to one side, the plate should be oriented with the long axis in the direction of the load. We mark the plate and the recommended orientation on the drawing, and the gasket is cut to match so it cannot be fitted the wrong way round.
Practical point: if the frame is washed down, tell us. A sealed base plate traps water that gets in from above, so a wash-down frame normally needs a drain path at the base rather than a full seal — and occasionally a small drain hole drilled in the lowest point of the leg.
It is supplied loose with the plate and the bolts, so it cannot be damaged in transit. It is fitted during assembly and is held in position by the plate bolts.
Yes. For a dry indoor frame the gasket adds nothing and can be left off, which is the cheaper option.
It stops water entering at the base, which is the main path. A leg that is open at the top can still take water in there, so a top cap or a sealed joint is also needed on a wash-down frame.
No, the hole pattern and the gasket are cut for the 40 × 80 section. A 40 × 40 leg takes the square base plate instead.
The four Ø11 mm holes take M10 anchors. The anchor type follows the floor: mechanical or chemical into a slab, a through-bolt with a spreader on a raised floor.
Send the profile section and tell us whether the frame is hosed down or outdoors. We will confirm whether the plate needs a seal or a drain path, and return FOB pricing within one working day.