Aluminium Profile Stair Stringer 45 x 90 mm for Access Platforms

OEM / ODM Available Free Sample Available Material certificate to EN 10204 3.1 on request, dimensional report per lot, RoHS and REACH declarations

45 x 90 mm six slot heavy aluminium profile at about 4.85 kg/m, cut and drilled for use as a stair stringer on access platforms, with M10 T-nut fixing for treads and rail posts.

Wholesale Price Quoted per metre or per flight against length, drilling and finish per metre or per set
Material Aluminium
Alloy Grade 6063-T5
Temper T5
Section Size 45 x 90 mm, six slots
Slot 6 x 10.2 mm groove, 10 mm mouth, 45 mm pitch, M10 hardware
Length Cut to the stringer length, drilled to the tread positions on the drawing
Tolerance Cut length +/-0.5 mm, hole position +/-0.2 mm, section to EN 755-9
Surface Mill finish / clear anodised / black anodised
MOQ 100 m or one flight, whichever is greater
Lead Time 2 to 3 weeks for mill finish, plus about a week for anodising
Loading Port Shanghai / Ningbo
Supply Ability Extrusion and machining of stringer pairs to a tread drawing, with the mirror pair produced together
Payment Terms T/T 30% deposit + 70% before shipment | L/C at sight
Trade Terms FOB | CIF | EXW
Certifications Material certificate to EN 10204 3.1 on request, dimensional report per lot, RoHS and REACH declarations
Request a Quote Reply within 24 hours
Aluminium profile access stairway and mobile work platform with guard rails
A profile access stair. The stringer is the part that decides the span, and the span is decided by deflection rather than by strength.

01What actually limits the span of a profile stair stringer?

Deflection, almost every time. An aluminium 45 x 90 mm stair stringer at about 4.85 kg/m is strong enough for a person on a tread by a wide margin, and it is still the wrong section if it bends enough to feel like a spring. Access stairs are judged by how they feel underfoot, and a stair that deflects visibly gets rejected regardless of its factor of safety.

The usual working limit is span divided by 300. For a 2.4 m stringer that is 8 mm, and 8 mm is roughly where a stair stops feeling solid. That number, not the yield strength, is what sets the section.

Everything below is a calculation from stated assumptions, written so that an engineer can repeat it with their own numbers. It is not a structural design and it does not replace one. We supply extrusion; the stair, its guard rails and its compliance are the designer’s scope.

02How do you size the stringer for a span?

Start from the tread load, split it between two stringers, and solve for the second moment of area that keeps deflection inside the limit. For a simply supported beam with a central point load, delta = P x L^3 / (48 x E x I), and setting delta to L/300 gives a direct expression for the required I:

Formula
I required = 6.25 x P x L^2 / E
Assumed tread load
1.5 kN, shared between two stringers
P per stringer
750 N
E, aluminium
70 000 N/mm2
Simplified
I required = 0.06696 x L^2, with L in mm
Stringer spanRequired IComment
1000 mm6.7 cm4A 40 x 40 four slot section is marginal here
1500 mm15.1 cm4Above what a 40 x 40 section provides
2000 mm26.8 cm4The 45 x 90 section is comfortable
2400 mm38.6 cm4Typical maximum for a single 45 x 90 stringer
3000 mm60.3 cm4Step up to a deeper section, or add a mid support

Two things about that table are worth spelling out. First, the requirement grows with the square of the span, so the last row is not twice the third row, it is more than twice. Second, a 40 x 40 section is in the region of 8 cm4, which is why a 40 x 40 stringer only works up to about a metre — and why a 40 x 40 stair that “seems fine” at 1.2 m is a stair that bounces at 1.8 m.

For this section, a rough estimate from the mass puts it well above every requirement in the table, which is consistent with the practical range of about 1.5 to 2.4 m per stringer. Check the actual I against the section data sheet rather than trusting the estimate — the estimate assumes an average wall and ignores the slot grooves.

03Why does a stair fail at the connection before it fails at the beam?

Because a stringer is not a simply supported beam in reality. It is bolted to a platform at the top and to a floor plate at the bottom, and those two connections decide whether the calculated deflection is what you get.

What goes wrongWhat you feelWhyFix
Top connection is a single boltThe stair rocks sideways when somebody walks upA single bolt is a pin joint with no rotational restraintTwo bolts or a bracket with a face that bears on the platform
Bottom is not fixed downThe foot slides and the flight driftsThe bottom of a stair pushes outward under loadA floor plate with two anchors, or a tie back to the platform
Stringers not parallel and plumbTreads are not level and the flight twistsAccumulated setting-out errorSet out both stringers from one datum, not from each other
Tread fixings in the slot onlyTreads creak and work looseThe T-nut bears on the slot flange and creeps under foot trafficTwo T-nuts per tread end, or a through bolt with a plate
Guard rail posts bolted to the stringer webThe rail moves when leaned onThe stringer web is thin and the post is a leverRail posts into the slot with a backing plate, or a separate rail frame

The last row is the one that surprises people. A guard rail post is a cantilever, and a person leaning on it applies a load at the top of a lever arm of about a metre. A single bolt into the stringer web will move visibly. The post needs either a backing plate that spreads the load along the slot, or its own frame.

04How are the treads fixed?

Two M10 T-nuts per tread end, in the stringer slot, is the normal arrangement. The slot gives adjustment, which matters because the tread pitch has to be right for the whole flight, not just the first step.

05What is our scope, and what is not?

This matters more on a stair than on any other page, so it is stated plainly rather than in a footnote.

What we supply

  • 45 x 90 mm extrusion, cut to the stringer length
  • Slots for tread fixing and rail fixing
  • Drilling and tapping to a drawing, if the connection positions are given
  • Finish: mill, anodised, or coated
  • Material certificate and dimensional report on request

What we do not supply or certify

  • The structural design of the stair or the platform
  • Guard rail design, height or load resistance
  • Compliance with the access standard that applies to your machine or building
  • Anchor design into the floor or the platform
  • Any statement that a finished stair is safe to use

Access stairs to machinery are covered by standards such as EN ISO 14122-3, which sets the rail heights, the load cases and the geometry. Those requirements are the designer’s to apply and to certify. What we can do is supply extrusion that meets the section tolerance and the alloy you specify, and cut and machine it accurately — which is the part we are actually good at.

06What about the platform itself?

The same section works for platform framing, with one difference: a platform beam is loaded by a distributed load rather than a point load, so the deflection calculation is different and generally kinder at the same span. Use delta = 5 x w x L^4 / (384 x E x I) for a uniformly distributed load, with the same L/300 limit.

Two practical notes on platforms. Decking adds stiffness if it is fixed to the beams properly — a screwed deck acts as a diaphragm and stiffens the frame in plane, which is why the deck fixing pattern matters and not just the deck thickness. And a platform is a frame, not a set of beams: bracing in the horizontal plane is what stops it parallelogramming, and it is the first thing to be left out.

45 x 90 mm six slot heavy aluminium profile section used as a stair stringer
Six slots on a 45 mm pitch. The two slots on the wide face are where the treads go, and the two on the narrow face are where the rail posts go.

Stair stringer checklist

  • Stringer span, measured along the stringer, not the horizontal projection
  • Tread load assumption, and the deflection limit being applied
  • Section, and its second moment of area against the requirement
  • Top connection: how many bolts, and whether it bears on a face
  • Bottom connection: floor plate with anchors, and whether it needs a tie back
  • Tread pitch, and the fixing pattern per tread end
  • Guard rail post fixing, and whether a backing plate is needed
  • Decking and bracing for the platform, if there is one
  • Who is designing and certifying the stair, and to which standard

07Questions from fabricators and project engineers

Related sections and categories

Browse Stairway and Platform Systems, 45 Series Aluminium Profiles, or see the 45 x 90 mm six slot heavy section for the full section data, and the 45 x 180 mm ten slot section when the span needs more depth than 90 mm gives.

What span can a 45 x 90 aluminium profile stair stringer cover?

About 1.5 to 2.4 m per stringer, set by deflection rather than strength. The requirement for I rises with the square of the span, so the answer moves quickly as the flight gets longer.

Why not use a 40 x 40 profile for a stair stringer?

Because its second moment of area is roughly a third of what a 1.5 m span needs at an L/300 limit. It will carry the load and it will feel springy, and springy stairs get rejected.

How many fixings per tread?

Two M10 T-nuts per tread end in the stringer slot. One fixing lets the tread rotate under an eccentric load and it will creak.

Can the guard rail posts be fixed to the stringer?

Yes, into the slot with a backing plate that spreads the load along the slot. A single bolt into the web moves visibly when somebody leans on the rail.

Do you design or certify the stair?

No. We supply extrusion cut and machined to your drawing. The structural design, the guard rail design and compliance with the applicable access standard are the designer’s scope.

What finish should an outdoor stair use?

Anodised at AA20 or above for sheltered outdoor use, and consider a mill finish with a maintenance regime for a heavily used stair. Bare cut ends are always the first place corrosion appears, so specify end caps.

What to send for a stringer quote

  1. Stair geometry: total rise, going, number of treads, stringer span
  2. Tread load assumption and the deflection limit you are designing to
  3. Section, or the span so we can suggest one
  4. Tread fixing positions, or the drawing with them marked
  5. Guard rail post positions and fixing type
  6. Top and bottom connection details
  7. Finish, and whether cut ends need caps
  8. Whether a material certificate and dimensional report are required
  9. Quantity of flights, and whether left and right hand are mirror images

Send the tread fixing positions if you have them. A stringer cut to length is a simple order; a stringer drilled for treads is the one that saves the assembly time.

Send the stair geometry

Total rise, going, tread count and the stringer span are enough to size the section. Send the tread positions as well and the stringers arrive drilled as a mirror pair.

Request a quotation